3-24 Quadrus EZ Reader User’s Manual
Capture Timing
Time Between Captures
Note: Number of Captures and number of delays (Time Between Captures) must be
the same.
Time Delay Between Captures
Usage:
This is useful in applications where more than one symbol can appear dur-
ing a single read cycle (multisymbol), or where line speeds are slow enough
that captured frames might overlap or miss a symbol.
Definition:
A time delay can be inserted between individual frame captures in the
Rapid Capture mode.
Serial Cmd:
<K242,time before 1st capture,time between captures
[time1,time2,...time7]>
Entering 0’s will result in no time between captures (Diagram A).
Entering a different value in each field will vary the time delays accordingly.
(Diagram B)
Note: You must enter time values along with comma separators for each
field you want to change. If you omit fields, or enter only commas, the fields
will remain as previously set.
Default: 0
Options: 0 to 65535 (2.097seconds, in 32µS increments)
Diagram A
Start of Read Cycle
End of
read cycle
Time Delay Between Captures varies.
Time Delay Between Captures = 0
Diagram B
32145