Quadrus EZ Reader User’s Manual 8-7
Diagnostics
Service Message
Service Message Status
Service Message
Threshold
Resolution
Definition:
When enabled, a message is sent whenever the system detects that a
user-set service time has expired.
The service timer is reset on power-on, thus the timer only records the time
that has elapsed since the last reset.
The message is sent every time the timer expires.
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: SERVICE
Options: Any 1 to 10 ASCII characters except NULL < , or >.
Definition:
Sets the number of hours or minutes that will transpire before the service
message is output.
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 300 (5 minutes)
Options: 1 to 65,535
Definition: Records time in seconds or minutes.
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: Seconds
Options: 0 = Seconds 1 = Minutes