3-14 Quadrus EZ Reader User’s Manual
Serial Trigger
Start Character (non-delimited)
Stop Character (non-delimited)
Definition:
A single ASCII host serial trigger character that starts the read cycle and is
not enclosed by delimiters such as < and >.
Serial Cmd: <K229,start character>
Default: NULL (00 in hex) (disabled)
Options: Two hex digits representing an ASCII character except <, >, XON, and XOFF.
Usage:
It is useful in applications where different characters are required to start
and end a read cycle.
Definition:
A single ASCII host serial trigger character that ends the read cycle and is
not enclosed by delimiters such as < and >.
Serial Cmd: <K230,stop character>
Default: NULL (00 in hex) (disabled)
Options: Two hex digits representing an ASCII character except <, >, XON, and XOFF.