I/O Parameters
Green Flash Duration
Note: Green Flash Duration values only take effect in Static Presentation Mode.
Beeper
Note: Beeper will also sound if any of the following occur:
the reader is defaulted
a send/save command from ESP or an Exit command from any embedded menu
at the conclusion of a calibrate procedure
•a <Z>, <Zp>, <Zd>, or <K701,1> command is sent
Usage: A visual verification that a good read has occurred.
Definition:
When a good read occurs, the Green flash LED's will illuminate and stay on
for the time set for the Green Flash Duration value.
Serial Cmd: <K750,green flash mode,x-pattern status,green flash duration>
Default: 100 (1 second)
Options: 0 to 65535 (in 10mS increments)
Usage: An audible verification that either a good read or a noread has occurred.
Definition: A beep is emitted either after each good read or noread.
Serial Cmd: <K702,beeper status>
Default: Good Read
Options:
0 = Disabled
1 = Good Read
2 = Noread