5-12 Quadrus EZ Reader User’s Manual
Bad/No Symbol Qualification
2D Symbology Qualification
Note: in the cases where Symbol Size Status, Dimension Status, or Orientation Status
is enabled, the reader will always check the finder pattern regardless of Finder Pattern
Status setting.
Finder Pattern Status
Symbol Size Mode (2D Symbology Qualification)
Note: if Symbol Size 1 is larger than Symbol Size 2, it will be automatically reversed in
the algorithm.
Disabled
Decoded messages are output, but no attempt to qualify symbols or output Bad or No
Symbol messages is undertaken.
Bad/No Symbol Output
Checks first for decodes. If no symbol is decoded, checks for symbol size. If both Symbol
Size 1 and Symbol Size 2 requirement are met, a Bad Symbol message is output. If both
are not met, outputs a No Symbol message.
Object Qualification
Checks first for matches to symbol size. If qualified, attempts to decode. If no decodes are
found within the specified read cycle parameters, outputs a Noread message.
Enable Both
Same as Object Qualification, except that if no objects qualify, then a No Symbol message
is output; if at least one object qualifies, then a Bad Symbol message is output.
Definition: Checks for the presence of finder pattern.
Serial Cmd:
<K718,finder pattern status,symbol size mode,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimen-
sion tolerance,orientation mode,orientation value>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition:
Specifies the outputs resulting from the results of searches for Symbol Size
1 and Symbol Size 2.
Serial Cmd:
<K718,finder pattern status,symbol size mode,symbol size 1,symbol size
2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimen-
sion tolerance,orientation mode,orientation value>
Default: Disabled
Options:
0 = Disabled
1 = Bad/No Symbol Output
2 = Object Qualification
3 = Enable Both