Quadrus EZ Reader User’s Manual 3-13
Read Cycle
Serial Trigger
Serial Trigger Character (delimited)
Note: Serial Data or Serial Data or Edge triggering mode must be enabled for Serial
Trigger Character to take effect.
Start and Stop Trigger Characters (non-delimited)
Usage:
Allows the user to define the trigger character and delimiters that start and
stop the read cycle.
Definition:
A serial trigger is considered an online host command and requires the
same command format as all host commands: that is, to be entered within
angle brackets delimiters < > or in the case of non-delimited triggers, define
individual start and stop characters.
Usage: Allows the user to define the trigger character that initiates the read cycle.
Definition:
A single ASCII host serial trigger character that initiates the read cycle.
A delimited trigger character is one that either starts or ends the read cycle
and is enclosed by delimiters such as < and >.
Serial Cmd: <K201,serial trigger character>
Default: Spacebar (corresponds to <SP> displayed in the embedded menu)
Options:
Any single ASCII character, including control characters, except NUL (00H),
an existing host command character, or an on-line protocol character. Control
characters entered on the command line are displayed in the menu as
mnemonic characters.
Usage:
It is useful in applications where different characters are required to start
and end a read cycle.
Definition:
A non-delimited trigger character is one that either starts or ends the read
cycle and is NOT enclosed by delimiters such as < and >.
Both Start and Stop non-delimited characters can be defined and will
function according to the trigger event, as follows:
When defining Start and Stop trigger characters, the following rules apply:
•In External Edge the reader looks only for the start trigger character and
ignores any end trigger character that may be defined.
•In External Level, the start trigger character begins the read cycle and end
trigger character ends it. Note that even after a symbol has been decoded
and the symbol data transmitted, the reader remains in External Level
trigger read cycle until a Stop character is received.
•In Serial Data & Edge trigger mode, command, either a start trigger
character or a hardware trigger can start an edge trigger read cycle.
Kommentare zu diesen Handbüchern