Seitenansicht 157
5-42 Quadrus EZ Reader User’s Manual
Output 1 Parameters
Trend Analysis (Output 1)
Note: Output On under Output 1 Parameters must be set to Trend Analysis for this
output to function.
Under Output 1 Parameters, expand the Trend Analysis tree.
Usage:
Useful in cases in which the user doesn’t want to shut down for one condition
but wants to monitor quality and read conditions.
Definition:
Applies trend analysis settings to Output 1.
With Trend Analysis, the user can track the occurrences and frequency of
mismatches, noreads, and the number of reads per trigger and output the
results to any of three outputs.
Example:
Trend analysis mode = Noread
Number of Triggers = 25
Number to Output On = 4
In this example, the reader will activate an output when 4 noreads occur
within a period of 25 triggers (read cycles).