
Quadrus EZ Reader User’s Manual 3-23
Read Cycle
Capture Timing
Note: Capture Timing applies only to Rapid Capture mode.
Time Before 1st Capture
Time Before First Capture
Usage:
In almost any moving line application, a time delay is needed to ensure that
a symbol will be in the reader’s field of view at the beginning of the capture
sequence.
Definition:
Time Before 1st Capture in a moving line application is the time between
an external trigger event and the occurrence of the first capture.
Serial Cmd:
<K242,time before 1st capture,time between capture 1 and 2,,,,,,,,time
between capture 7 and 8>
Default: 0
Options: 0 to 65535 (2.097seconds, in 32µS increments)
Start of
read cycle
Time Before First Capture
Processing
Kommentare zu diesen Handbüchern