Quadrus EZ Reader User’s Manual 5-11
I/O Parameters
Minimum Number of Qualified Scan Lines
Start/Stop Status
Definition:
Sets the minimum number of scans that have the required number of bars
set in Minimum Number of Bars.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified
scans,start and stop status>
Default: 0
Options: 0 to 11 (0 is disabled)
Definition:
When enabled, both Start and Stop characters need to be present to qual-
ify as a decodable symbol. In the case of PDF417, only a Stop or Stop
needs to be present.
Note: This parameter does not apply to UPC, Pharmacode, RSS and Micro
PDF417.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified scans,start
and stop status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled