Microscan Quadrus EZ Bedienungsanleitung Seite 114

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 366
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 113
4-30 Quadrus EZ Reader User’s Manual
Symbology ID
Symbology ID
Explanation of Modifiers for Code 39, Codabar, and I2/5
For Code 39, Codabar and I 2/5, the modifier indicates Check Digit and Check Digit
Output status.
For Code 39 only, Full ASCII needs to be enabled to see modifiers 4, 5, and 7.
Example:]A5 indicates a Code 39 symbol with Check Digit and Check Digit Output
enabled and Full ASCII conversion performed.
Explanation of Modifiers for Other Symbologies
For Code 128, a 1 indicates ECC/EAN-128; otherwise the modifier is a 0.
For QR Code, a 0 indicates Model 1; a 1 indicates Model 2.
For all other codes, the modifier is 0.
Usage: Used when the symbology type and how it’s decoded needs to be known.
Definition:
Symbology ID is an ISO/IEC 16022 standard prefix set of characters that
identifies the symbol type.
When enabled, the reader analyzes and identifies the symbology and adds
a three character identifying prefix to the data:
1. ] (close bracket character) indicating the presence of a symbology ID
2. A, C, E, I, L, Q, b, d, p
A = Code 39; C = Code 128; E = UPC/EAN; I = I–2/5; L = PDF417; Q =
QR Code; b = BC412; d = Data Matrix; p = Pharmacode
3. Modifier
Serial Cmd: <K450,narrow margins,symbology identifier status>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Modifier Check Digit
Check Digit
Output
Full ASCII conversion performed
(Code 39 only)
0 Disabled N/A No
1 Enabled Enabled No
3 Enabled Disabled No
4 Disabled N/A Yes
5 Enabled Enabled Yes
7 Enabled Disabled Yes