5-44 Quadrus EZ Reader User’s Manual
Output 1 Parameters
Number of Triggers (Trend Analysis)
Number to Output On (Trend Analysis)
Definition: The number of triggers to examine for the trend analysis condition.
Serial Cmd: <K780,trend analysis mode,number of triggers,number to output on>
Default: 0
Options: 0 to 255
Usage:
For example, if Number to Output On is set to 3 and Trend Analysis Mode
is set to Noread, then the output will not be activated until 3 noreads have
occurred.
Definition:
Sets the number of Trend Analysis Mode events (mismatches, noreads or
reads/trigger as configured by Trend Analysis Mode) to occur within the
trigger evaluation time period before activating the associated output.
Serial Cmd: <K780,trend analysis mode,number of triggers,number to output on>
Default: 0
Options: 0 to 255