Microscan QX Hawk Bedienungsanleitung Seite 417

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 460
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 416
QX Hawk Industrial Imager User Manual A-101
Appendices
User Defined Tag Echo, Command Echo, Output Control Echo
These are a direct echo of the equivalent fields in the OUT assembly. They provide the
PLC programmer with a method of verifying that the OUT data has been received by QX Hawk.
External Input Status (Physical Pin State)
0 = no current sensed on input
1 = current sensed on input
External Output Status (Physical Pin State)
0 = output contact is open
1 = output contact is closed
Device Status
Bit # Pin Name
0 Trigger
1 New Master
2-31 Reserved
Bit # Pin Name
0Out1
1Out2
2Out3
3-31 Reserved
Field # Bit Name State
0 Reserved
1
New Master
Requested
1 = New Master Requested
2-7 Reserved
8 Scanning Disabled 1 = Scanning Disabled
9-15 Reserved
16 In Read Cycle 1 = In Read Cycle
17 Actively Scanning 1 = Active Scanning
Seitenansicht 416
1 2 ... 412 413 414 415 416 417 418 419 420 421 422 ... 459 460

Kommentare zu diesen Handbüchern

Keine Kommentare