A-28 QX Hawk Industrial Imager User Manual
Serial Commands
Serial Command Format
Microscan readers are controlled by two types of serial commands: configuration commands
and utility commands.
Rules that apply to both configuration and utility commands
Less than ‘< and greater than >’ angle bracket characters enclose the commands.
Commands and data are case sensitive. Characters must be entered as upper or lower
case, as specified.
Serial Utility Commands
Serial Utility Commands are sent during operations and are not followed by <A> or <Z>.
Serial Configuration Commands (K Commands)
Microscan’s serial configuration commands begin with a single “K” character followed by a
3-digit numeric character, comma-separated command fields, and an initializing command,
as follows:
<Knumeric character,data,data,...etc.><initializing command>
An initializing command <Z> or <A> may follow the command.
<Z> initializes the imager’s memory and saves for power-on.
<A> initializes the imager’s memory but does not save for power-on.
For example, to enable UPC and save the change for power-on, send <K473,1><Z>.
To change Baud Rate and reset without saving changes for power-on, send
<K100,3><A>.
Serial Configuration Command Conventions
All command fields (except the last) must be followed by a comma (without a space).
NULL cannot be used. The characters <, >, and
, can be used, but only if entered as
hex pairs (see ASCII Character Entry Modifier).
All fields preceding a modified field must be included.
If there is no change in preceding fields, then commas alone can be entered in these
fields. For example, if only the last field in the following command is changing,
<K100,4,1,0,0> can be entered as <K100,,,,0>.
All fields following a modified field can be omitted. For example, to change Baud Rate
only, send <K100,3>.
Concatenating Configuration Commands
Commands can be concatenated (added together) in a single string. For example,
<K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New
Trigger, enables Narrow Quiet Zone, and resets the data buffers without saving the
changes for power-on.