A-42 QX Hawk Industrial Imager User Manual
Serial Commands
Read Cycle
Trigger Mode / Filter Duration
Trigger Mode (Trigger Mode / Filter Duration)
Leading Edge Trigger Filter (Trigger Mode / Filter Duration)
Trailing Edge Trigger Filter (Trigger Mode / Filter Duration)
Serial Trigger Character (Delimited)
Trigger Mode / Trigger Filter Duration
<K200,trigger mode,leading edge trigger filter duration,trailing
edge trigger filter duration>
Serial Trigger Character <K201,serial trigger character>
External Trigger State <K202,external trigger state>
End of Read Cycle <K220,mode,read cycle timeout>
Decodes Before Output <K221,number before output>
Multisymbol <K222,number of symbols,multisymbol separator>
Serial Trigger Start Character <K229,start character>
Serial Trigger Stop Character <K230,stop character>
Capture Mode <K241,mode,number of captures,rapid capture mode>
Capture Time
<K242,time before first capture,time between 1-2,time between
2-3,time between 3-4,time between 4-5,time between 5-6,time
between 6-7,time between 7-8>
Store No Read Image <K244,image storage type,image storage mode>
Image Processing Timeout <K245,image processing timeout>
Number of Symbols in Field of View <K518,number of symbols in field of view>
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: 0 = Continuous Read
Options: 0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: 313 (~10 ms)
Options: 1 to 65535 (x 32.0 µs)
Serial Cmd: <K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
Default: 313 (~10 ms)
Options: 1 to 65535 (x 32.0 µs)
Serial Cmd: <K201,serial trigger character>
Default: Space (0x20)
Options: Any 7-bit ASCII character