A-54 QX Hawk Industrial Imager User Manual
Serial Commands
Pharmacode
Status (Pharmacode)
Fixed Symbol Length Status (Pharmacode)
Fixed Symbol Length (Pharmacode)
Minimum Bars (Pharmacode)
Bar Width Status (Pharmacode)
Direction (Pharmacode)
Fixed Threshold Value (Pharmacode)
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 0 = Disabled
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 10
Options: 1 to 16
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 4
Options: 1 to 16
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 0 = Mixed
Options: 0 = Mixed
1 = All Narrow
2 = All Wide
3 = Fixed Threshold
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 0 = Forward
Options: 0 = Forward 1 = Reverse
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
bars,bar width status,direction,fixed threshold value>
Default: 400
Options: 1 to 65535