PDF417
Save changes whenever you reconfigure Imager settings.
7-16 COPYRIGHT © 2005 MICROSCAN SYSTEMS
Save
Settings
Clear
all Data
Default
to USB
Clear XML
Rules
Default
to PS2
PDF417
Read the following symbols to enable/disable PDF417 symbology settings:
If your data is encoded into multiple PDF417 symbols, the Macro PDF417 feature allows
a user to read these PDF417 symbols and combine the information. The Macro PDF417
function has the following limitations:
1. You can read non-Macro PDF417 symbols in the middle of a Macro PDF417 file.
They will be uploaded immediately. The incomplete Macro PDF417 segments will
be buffered.
2. Scanning a Macro PDF417 symbol with a file ID different than the Macro PDF417
segments already stored will cause the stored segments being deleted (aborted)
and you will hear beeps. The new file starts with this symbol.
3. The MS-Q only supports up to 16 file segments. When the buffered segments reach 16
and the file is still not complete, you will hear 3 beeps and all the buffered segments
will be deleted.
4. You cannot read a segment of the same file more than once.
Available for Basic Mode only.
PDF417 On (default) PDF417 Off
Macro PDF417 On Macro PDF417 Off (default)