Unique Identifiers
Save changes whenever you reconfigure Imager settings.
Save
Settings
Clear
all Data
Default
to USB
Clear XML
Rules
Default
to PS2
12-5
COPYRIGHT © 2005 MICROSCAN SYSTEMS
Error Messaging
This feature is used to validate that UID message streams are in the correct format. When
Error Messaging is enabled, the MS-Q sends a message to the host indicating an error
every time a bad symbol is read. The table below shows examples of error messages.
Table: Examples of error messages
Invalid Format
Header
[)>{RS}15{GS}800406141411A0B9C3D6{RS}{EOT}
Error message: “Invalid UID Format Header”
Invalid AI
(01 + 21)
[)>{RS}05{GS}0100061414199999{GS}
31
1A0B9C3D6{RS}{EOT}
Error message: “Invalid AI”
Invalid DI
(UN + 12V + 1P + S)
[)>{RS}06{GS}
12X
077991289{GS}1P4202435{GS}S10936{RS}
{EOT}
Error message: “Invalid DI”
Invalid TEI
(D + CAG + SER)
[)>{RS}DD{GS}CAX987654{GS}SERMKLJHUIYD{RS}{EOT}
Error message: “Invalid TEI”
Space in Data
Qualifier
[)>{RS}05{GS}8 0040614 1411 A0 B9 C3D6{RS}{EOT}
Error message: “Invalid AI (or DI or TEI depending on format in
use)”
Lower Case
Characters
[)>{RS}05{GS}800406141411a0B9C3d6{RS}{EOT}
Error message: “Invalid Characters in Data”