Performing a Manual Battery Recharge
6-6 COPYRIGHT © 2005 MICROSCAN SYSTEMS
Performing a Manual Battery Recharge
If the MS-Q’s lithium ion battery is allowed to lose 100% of its charge, the Imager will
become locked in a continual vibration cycle. The mechanism of vibration is the same as
the “successful decode” indicator, which can be switched between beep and vibrate.
However, when the Imager vibrates to indicate total loss of battery charge, it is unable
to decode symbol data and it cannot be defaulted.
To recover from this vibration cycle, it is necessary to follow these steps in order to
“jump-start” the Imager and provide enough charge to perform a default:
1. Remove the battery.
2. Align the battery with its housing on the side opposite the sliding latch mechanism.
Hold the battery at an angle from its housing,
balanced where the battery’s tab is aligned
with the housing’s slot.
3. Starting from the angled position described in step 2, lower the battery completely
into its housing
three times
, but do not engage the sliding latch mechanism until
the third time the battery is inserted.
4. The third and final time the battery is lowered and inserted, leave it in its housing
and move the sliding latch mechanism into its locked position.
5. Default the Imager.
For best results, charge the battery fully before you next use the Imager.
The battery should be inserted for
slightly less than one second each time it
is lowered. Maintain a steady rhythm
while performing this sequence.