Appendices
Appendix B — Electrical Specifications
Power: 3.5 Watts (max.)
5VDC +/– 5%, 200 mV p-p max. ripple, 440 mA @ 5VDC (typ.)
Optional Int: 10-28V Accy
Host Connector / Pin Assignments
High Density 15 Pin D-sub Socket Connector
a. Can sink 10 mA and source 10 mA.
b. The default is activated by connecting pin 8 to ground pin 4.
c. Chassis ground: Used to connect chassis body to earth ground only. Not to be used as power or signal return.
Optoisolator Outputs
Optoisolator circuits can transfer pulses between the imager and peripherals with no direct
connection with the imager’s internal circuitry. However, not every optoisolator configuration
provides complete isolation. The following diagrams show both fully optoisolated and
non-optoisolated circuits. They are only examples and do not represent all the possible
wiring configurations.
Pin Host RS-232 Host/Aux RS-232 Host RS-422/485 In/Out
1 Power +5 VDC In
2 TxD TxD TxD(–) Out
3 RxD RxD RxD(–) In
4 Power/Signal Ground
5 NC
6 RTS Aux TxD TxD(+) Out
7 Output 1 TTL a Out
8 Default configuration b In
9 Trigger In
10 CTS Aux RxD RxD(+) In
11 Output 3 TTL a Out
12 New Master (NPN) In
13 Chassis ground c
14 Output 2 TTL a Out
15 NC
I
load
=5mA I
load
=50mA I
load
=100mA
V
Out-On
a
a. Voltage drop across output when activated.
0.5V 0.5V 1.0V
t
On-Typ
5mS 0.7mS 0.8mS
t
Off-Typ
S S S
I
Load
Scanner
Output
Outputs (+)
Outputs (–)