EZ Match User Manual
11-33
Camera and IP Setup
Symbol Direction
If a symbol enters the field of view from the left, it will be skewed as shown in the image
below. The image is processed from top to bottom, meaning that the top of the symbol is
captured first. The amount of skew is dependent on the speed at which the symbol moves
through the imager’s field of view. The symbol below was captured at a line speed of 40
inches per second.
Additional Notes on Skew Correction
When skew correction is enabled, the pre-processing option in Capture Mode is disabled,
rega
rdless of how it is configured. This is because image distortion
must be corrected
before any other image processing can occur.
Calibration does not perform skew correction. It is assumed that during calibration the
symbol is stationary, so skew correction is not required.
Images are corrected before they are processed. Therefore, if an image is still pendi
ng
at
the end of the read cycle, it will not have been skew-corrected.
Definition: This feature specifies the direction the symbol is moving through the
imager’s field of view, or which side of the field of view the symbol will enter
first.
Note: Image captures of symbols entering the field of view from above or
below cannot be skew-corrected.
Usage: <K537,line speed,symbol direction>
Default: Right
Options: 0 = Right 1 = Left