11-12
EZ Match User Manual
Window of Interest
Window of Interest by Serial Command
The figure below shows where to locate the start position of the row and column pointers
and how to measure the column depth and row width dimensions.
Top (Row Pointer)
Left (Column Pointer)
Important: The column pointer setting must be an even value. If a user enters an odd
value, it will be decreased automatically to the nearest even value. For example, if a user
enters a setting of 101, it will automatically be reduced to 100 (although a user request for
this setting would still show 101).
Definition: Defines the row position of the upper-left starting point of the window.
Serial Cmd: <K516,row pointer,column pointer,row depth,column width>
Default: 0
Options: Monochrome EZ Match: 0 to (1024 – row depth)
EZ Match Color: 0 to (832 – row depth)
Definition: Defines the column position of the upper-left starting point of the window.
Serial Cmd: <K516,row pointer,column pointer,row depth,column width>
Default: 0
Options: Monochrome EZ Match: 0 to (1280 – column width)
EZ Match Color: 0 to (2048 – column width)
WOI Column
Pointer
WOI Row Pointer
WOI Column Width
WOI Row Depth