14-4
EZ Match User Manual
Read Rate
Read Rate
Read Rate by ESP
You can access Read Rate from the Utilities view under the Read Rate tab.
To see the number of decodes per second, click the Decodes/sec radio button and click
the Start button.
To see the percentage of decodes, click the
Percent
radio button and then the
Start
button.
To end a Read Rate test, click the Stop button (the Start button becomes a “Stop” button
during an active Read Rate test.)
Important: When Read Rate is enabled, the IP Database is not active, regardless of how
the imager is configured.
Read Rate by Serial Command
Enter Decodes / Second Test
Sending <C> instructs the imager to transmit the decodes per second and symbol data
(if any). The decode rate can vary dramatically due to the angle and location of the symbol
in relation to the field of view. This test is very useful in aligning and positioning the imager
during setup.
Enter Percent Test
Sending <Cp> instructs the imager to transmit the percentage of decodes and any
decoded symbol data.
End Read Rate Test
Sending <J> ends both the Percent test and the Decodes/Second test.
Tube/Cap Detection Notes
1.
If Tube/Cap Detection operations are enabled in the
<K260>
Multi-Operation
command,
they
will be part of Read Rate output. The formatted message will follow the Tu
be/Cap
Detection message setup.
2. Active symbologies for Read Rate are determined in the same way, regardless of ho
w
Multi-Operation
is configured.
3.
Tube Angle is not part of Read Rate output. See the the
<K850>
Configurable Output 1
com
mand for further details.
4. If enabled, Library Index is part of Read Rate output. Tubes or caps with differ
ent
library indexes are treated as different objects. See the the
<K850>
Configurable Output 1
com
mand for further details.
Kommentare zu diesen Handbüchern