Calibration Serial Commands
Calibration Serial Commands
Calibration Overview
Calibration is one of the most powerful features of the EZ Match Imager. The calibration
process can be initiated by serial command, EZ Button, or ESP user interface.
When the imager enters calibration, it runs through an optimization cycle that sets the ideal
parameters for reading symbols at the highest possible level of performance. Calibration can
be specially configured to optimize specific parameters, such as gain, shutter speed, and
symbol type.
The calibration process consists of five separate phases: search pass, medium pass, and
fine-tune pass. During this process the imager quickly locates configuration setup, defines
a calibration range for the configuration parameters, and then tunes those parameters for
optimal performance.
Calibration Options <K529,gain,shutter speed,symbol type,WOI framing,WOI
margin,line scan height,processing>
Calibration
<
@CAL
>