Copyright ©2010 Microscan Systems, Inc. 7
MS-820-to-QX-830 Compact Industrial Scanner Transition Guide
MS-820 Commands QX-830 Commands
MS-820 I/O Parameters (continued) QX-830 I/O Parameters (continued)
No Read Message <Kkstatus,message> No Read Message <K714,status,message>
Bad Symbol Message
<K’status,message> Bad Symbol Message <K715,status,message>
No Symbol Message
<KNstatus,message> No Symbol Message <K716,status,message>
Input 1 <K730,input mode,active state>
No Object Message <KOstatus,message>
Laser On / Off Status <KClaser on/off status>
Partial Output <KYstatus,start postion,length>
Green Flash LED
<
K750,
green flash mode,unused,
green flash duration>
Status Indicators <K751,status,bar graph,I/O 1,I/O 2>
Symbol Position
Output
<K758,scan status,separator>
Database Identifier
Output
<K759,status,separator character>
EZ Button <K770,status,default on power-on>
EZ Button Modes
<K771,single beep,two beeps,three
beeps,four beeps>
Auto Framing Options
<K773,laser framing>
Output 1
<Kvoutput on,active state,pulse
width,output mode,trend analysis
mode,trigger evaluation period,
number to output on,reads per
trigger threshold>
Output 2
<Kwoutput on,active state,pulse
width,output mode,trend analysis
mode,trigger evaluation period,
number to output on,reads per
trigger threshold>
Output 3
<K‘output on,active state,pulse
width,output mode,trend analysis
mode,trigger evaluation period,
number to output on,reads per
trigger threshold>
Trend Analysis
Output 1
<K780,trend analysis mode,number
of triggers,number to output
on,decodes per trigger>
Trend Analysis
Output 2
<K781,trend analysis mode,number
of triggers,number to output
on,decodes per trigger>
Trend Analysis
Output 3
<K782,trend analysis mode,number
of triggers,number to output
on,decodes per trigger>
Diagnostics Output 1
<K790,high temperature,service
unit,unused,laser current high,
laser current low,low temperature>
Diagnostics Output 2
<K791,high temperature,service
unit,unused,laser current high,
laser current low,low temperature>
Diagnostics Output 3
<K792,high temperature,service
unit,unused,laser current high,
laser current low,low temperature>
Output 1 Parameters
<K810,output on,output state,pulse
width,output mode>
Output 2 Parameters
<K811,output on,output state,pulse
width,output mode>
Output 3 Parameters
<K812,output on,output state,pulse
width,output mode>
For Assistance, contact the Automation Group at Cross 800.866.4568