Microscan MS-820 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
12 Copyright ©2010 Microscan Systems, Inc.
MS-820-to-QX-830 Compact Industrial Scanner Transition Guide
MS-820 and QX-830 Specifications
Mechanical
The mounting dimensions of the MS-820 and QX-830 are essentially the same, although the M12
receptacles at the back of the QX-830 may affect installation in some applications.
Environmental
Emissions
Laser Light
MS-820 QX-830
Enclosure Die-cast aluminum, IP54 rated Enclosure Die-cast aluminum, IP65 rated
Operating
Temperature
0° to 50° C (32° to 122° F)
Operating
Temperature
0° to 50° C (32° to 122° F)
Storage
Temperature
–50° to 75° C (–58° to 167° F)
Storage
Temperature
–50° to 75° C (–58° to 167° F)
Humidity Up to 90% (non-condensing) Humidity Up to 90% (non-condensing)
MS-820 QX-830
Heavy industrial EN 61000-6:1999 Heavy industrial EN 61000-6-2:2005
Radiated
emissions
EN 55022:1998 Class A 30-1000 MHz
Radiated
emissions
EN 55022:2006 Class A 30-1000 MHz
Conducted
emissions
EN 55022:1998 Class A .15-30 MHz
Conducted
emissions
EN 55022:2006 Class A .15-30 MHz
MS-820 QX-830
Output Wavelength
650 nm nominal (MS-825 infrared
option: 780 nm nominal)
Output Wavelength 655 nm nominal
Safety Class
Visible laser: CDRH Class II, 650
nm; Infrared Laser: CDRH Class I,
780 nm
Safety Class Visible laser: CDRH Class II, 655 nm
MS-820 Dimensions QX-830 Dimensions
.77”
19.6 mm
1.13”
28.7 mm
1.20”
30.5 mm
For Assistance, contact the Automation Group at Cross 800.866.4568