Microscan MS-820 Bedienungsanleitung Seite 4

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 3
4 Copyright ©2010 Microscan Systems, Inc.
MS-820-to-QX-830 Compact Industrial Scanner Transition Guide
MS-820-to-QX-830 Command Comparisons
The following table shows MS-820 commands on the left and QX-830 commands on the right. The name
of the command is shown first, and the parameters are shown to the right of the name.
Commands that have remained equivalent or near-equivalent from MS-820 to QX-830 are shown directly
opposite each other. Some MS-820 commands are not present in the QX-830, and some QX-830 commands
are new. This is indicated with gray boxes.
MS-820 Commands QX-830 Commands
MS-820 Communications QX-830 Communications
Host Port
Connections
<Kabaud rate,parity,stop bits,data
bits>
RS-232 A
<K100,baud rate,parity,stop bits,
data bits>
Host Protocol <Kfprotocol>
RS-422 Status <Kbstatus>
Auxiliary Port
<Kyaux port mode,baud rate,
parity,stop bits,data bits,daisy
chain status,daisy chain ID>
RS-232 B
<K101,status,baud rate,parity,stop
bits,data bits>
RS-422
<K102,status,baud rate,parity,stop
bits,data bits>
Ethernet
<K126,status,IP address,subnet,
gateway,IP address mode>
Ethernet TCP Ports <K127,TCP Port 1,TCP Port 2>
EtherNet/IP <K129,status>
RS-232 A Data Type
<K130,symbol data output,extra
symbol information,diagnostic
output, external source processing
mode>
RS-232 B Data Type
<K131,symbol data output,extra
symbol information,diagnostic
output, external source processing
mode>
RS-422 Data Type
<K132,symbol data output,extra
symbol information,diagnostic
output, external source processing
mode>
Ethernet TCP Port 1
Data Type
<K133,symbol data output,extra
symbol information,diagnostic
output, external source processing
mode>
Ethernet TCP Port 2
Data Type
<K134,symbol data output,extra
symbol information,diagnostic output,
external source processing mode>
EtherNet/IP Data Type
<K136,symbol data output,extra
symbol information,diagnostic
output, external source processing
mode>
Preamble <Kdstatus,preamble> Preamble <K141,status,preamble>
Postamble <Kestatus,postamble>Postamble<K142,status,postamble>
Response Timeout <KAresponse timeout> Response Timeout <K143,response timeout>
LRC Status <Kcstatus> LRC Status <K145,status>
ACK/NAK Options
<
K147,
RES,REQ,STX,ETX,ACK,NAK>
Polling Mode Options
<
K148,
RES,REQ,STX,ETX,ACK,NAK>
Autoconfiguration
Daisy Chain
<K150DAISY>
Protocol Selection
<
K160,
protocol,address,protocol port>
External Data Routing
<K161,mode,destination port,ambles
to source,echo to source,output at
end of read cycle,output at ETX,output
at Timeout>
Array Communication
Modes
<K162,mode,source,daisy chain i.d.
status,daisy chain i.d.>
Intercharacter Delay <KBintercharacter delay>
For Assistance, contact the Automation Group at Cross 800.866.4568
Seitenansicht 3
1 2 3 4 5 6 7 8 9 ... 13 14

Kommentare zu diesen Handbüchern

Keine Kommentare