MS-820-to-QX-830 Compact Industrial Scanner Transition Guide
MS-820 Commands QX-830 Commands
MS-820 Symbologies (continued) QX-830 Symbologies (continued)
Code 39
<Kpstatus,check digit status,check
digit output status,large intercharacter
gap,fixed symbol length status,fixed
symbol length,full ASCII set>
Code 39
<
K470,
status,check character status,
check character output status,large
intercharacter gap,fixed symbol
length status,fixed symbol length,full
ASCII set>
Codabar
<Kqstatus,start and stop match
status,start and stop output status,
large intercharacter gap,fixed
symbol length status,symbol
length,check digit type,check digit
output>
Codabar
<K471,status,start/stop match
status,start/stop output status,large
intercharacter gap,fixed symbol
length status,fixed symbol
length,check character type,check
character output status>
Interleaved 2 of 5
<Krstatus,check digit status,check
digit output,symbol length 1,symbol
length 2>
Interleaved 2 of 5
<
K472,
status,check character status
,
check character output status,symbol
length 1,symbol length 2,guard
bar,range mode status>
UPC/EAN
<KsUPCstatus,EAN status,
supplementals
status,separator
status,separator
character>
UPC/EAN
<K473,mode,EAN status,
supplementals
status,separator status,
separator
character,supplementals
type,UPC-E as UPC-A>
Code 128 / EAN 128
<Ktstatus,fixed symbol length status,
fixed symbol length,EAN-128 status
,
output format,application record
separator status,application record
separator
character,application
record brackets,application record
padding>
Code 128 / EAN 128
<K474,status,fixed symbol length
status,fixed symbol length,EAN
status,output format,application
record separator status,application
record separator character,application
record brackets,application record
padding,separation factor>
Code 93
<K!status,fixed symbol length
status,symbol length>
Code 93
<K475,mode,fixed symbol length
status,symbol length>
PDF417
<K[status,raster sweeps before
decode attempt,fixed length status,
symbol length>
PDF417
<K476,status,scan line limit,fixed
symbol length status,fixed symbol
length,decode at end of read cycle>
Pharmacode
<K477,status,fixed bar count status,
fixed bar count,minimum bar count,
bar width mode,direction,fixed
threshold value>
DataBar
Omnidirectional
(RSS-14)
<K482,status>
DataBar Limited
(RSS Limited)
<K483,status>
DataBar Expanded
(RSS Expanded)
<K484,status,fixed symbol length
status,fixed symbol length>
MicroPDF417
<K485,status,scan line limit,fixed
symbol length status,fixed symbol
length>
Symbol
Reconstruction
<K496,symbol reconstruction
redundancy,symbol reconstruction
effort>
MS-820 I/O Parameters QX-830 I/O Parameters
Calibration Options
<
K521,
unused,video,scan speed,laser
power,laser framing,symbology>
Serial Verification
<
KS
command echo status,command
beep status,control/hex output>
Serial Verification
<
K701,
serial command echo status,
serial command beep status,control/
hex
output>
Beeper <Kustatus,volume> Beeper <K702,status>
Quality Output
<KJquality output separator,
decodes/trigger status,decode
direction output>
Quality Output
<K704,quality output separator,
decodes/trigger status,decode
direction output>
Symbol Data Output
<Klsymbol data output status,when
to output>
Symbol Data Output
<K705,symbol data output status,
when to output symbol data,symbology
identifier status>
Read Duration
Output
<K706,status,separator>