Response Timeout
3-10 MS-880 Industrial Long Range Scanner User’s Manual
3–Protocol
Response Timeout
Definition: Time the scanner will wait before timing out if ACK, NAK, and ETX are
enabled, and a host response is expected.
Usage: Only used when a response is required from the host. While in Multi-
drop, if the scanner does not receive an ACK or NAK from the host
after sending polled data, it will act on a fault. The scanner can be set
to wait indefinitely by setting Response Timeout to zero.
Serial Cmd: <K143,response timeout>
Default: 2 (in ten mS increments)
Options: 0 to 255 (A zero (0) setting causes an indefinite wait.)