Chapter 11 Matchcode
MS-880 Industrial Long Range Scanner User’s Manual 11-15
11–Matchcode
Store Next Label Scanned as Master Label
1
Definition: After you’ve set the size in the database (“Master Label Database Size”
on page 11-11), you can order the scanner to scan-in the next label as
the master label for any given master label number.
ESP: In the Master Database tab, under the Output Format menu
1. Select the master label index number in which you want to store
the label data.
2. Click on the Scan Label into Selected Index.
Serial Cmd: <G master label number>
To store the next label scanned as master label #1, send: <G> or
<G1>.
To store next label scanned as the master label for any other master
label database number, send: <Gmaster label number [1-10]>.
For example, <G5> will cause the next label scanned to be entered as
master label #5.
Default: (no data)
1. While not strictly a configuration command, <G> is included here because it is so closely
related to other master label commands.
Seitenansicht 176