Microscan MS-4X Bedienungsanleitung Seite 189

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 312
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 188
Chapter 12 Outputs
MS-880 Industrial Long Range Scanner User’s Manual 12-11
12–Outputs
Quality Output
See “Reads per Trigger Threshold” on page 14-9.
Separator
Note: For all serial configuration commands, the following characters cannot be
used: , < > NUL
Reads/Trigger Status
Definition: Allows the host to track the number of good reads per trigger by
appending a five digit numeric field to the end of bar code label data.
When enabled, bar code data is followed by a separator, followed by the
five digits in the form of 00000. For example, a certain bar code that
has been averaging 00100 reads per read cycle suddenly drops to
00012, this would be a good indication that a problem has arisen even
though good reads are still occurring.
Usage: Host system can monitor scanning performance (printing process,
scanning environment changes, etc.) by setting thresholds in their pro-
cessing or displaying the outputs for visual verification.
Serial Cmd: <K704,quality output separator,reads/trigger status>
Default: , (comma)
Options: any ASCII character
Serial Cmd: <K704,quality output separator,reads/trigger status>
Default: Disabled
Options: 0 = Disabled
1 = Enabled