Auxiliary Port
2-14 MS-880 Industrial Long Range Scanner User’s Manual
2–Communications
Aux Port Communications Parameters
As with the host port parameters, the auxiliary terminal’s settings (baud rate, parity,
stop bits, and data bits) must be identical with those of the auxiliary device.
Baud Rate, Aux Port
Parity, Aux Port
Data Bits, Aux Port
Definition: The rate at which the scanner and host transfer data back and forth.
Usage: Can be used to transfer data faster or match an auxiliary device.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Default: 9600
Options: 1 = 1200 4 = 9600 7 = 57.6K
2 = 2400 5 = 19.2K 8 = 115.2K
3 = 4800 6 = 38.4K
Definition: An error detection routine in which one data bit in each character is
set to 1 or 0 so that the total number of 1 bits in the data field is even
or odd.
Usage: Only changed if necessary to match host setting.
Default: Even
Options: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Serial Cmd: 0 = None 1 = Even 2 = Odd
Definition: Number of bits in each character.
Usage: Only changed if necessary to match host setting.
Serial Cmd: <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain
ID status,daisy chain ID>
Default: Seven
Options: 0 = Seven 1 = Eight