Appendix D
A-12 MS-820 Industrial Bar Code Scanner User’s Manual
Appendices
Appendix D — Serial Configuration Commands
The following table is a list of all the available serial configuration commandsalphabet-
ical. These commands are also listed at the beginning of each applicable chapter. For
utility (operational) commands see Table 11-1, “Summary of Utility Serial Com-
mands,” on page 11-3.
Table A-9 Complete List of Serial Configuration Commands
Command Title Cmd Format
Host Port Parameters Ka <Kabaud,parity,stop bits,data bits>
Auxiliary Port Parame-
ters
Ky
<Kyaux port mode,baud,parity,stop bits,data bits,daisy chain sta-
tus,daisy chain ID>
Host Protocol Kf <Kfprotocol>
LRC Kc <Kcstatus>
Response Timeout KA <KAresponse timeout>
Intercharacter Delay KB <KBintercharacter delay>
Preamble Kd <Kdstatus,preamble>
Postamble Ke <Kestatus,postamble>
Comm. Status Request KT? <KT?>
Triggering Mode Kg <Kgtrigger mode,filter time>
End of Read Cycle Kh <Khmode,timeout>
Serial Trigger Charac-
ter
Ki <Kicharacter>
External Trigger State Kj <Kjexternal trigger state>
Decodes Before Output Km <Kmdecodes before output>
Multilabel KL <KLnumber of labels,multilabel separator>
Narrow Margins/Sym-
bology ID
Ko <Konarrow margins status,symbology ID status>
Background Color Kx <Kxbackground color>
Code 39 Kp
<Kpstatus,check digit status,check digit output status,large inter-
character gap,fixed code length status,fixed code length,full ASCII>
Interleaved 2 of 5 Kr <Krstatus,check digit,check digit output,length 1,length 2>
UPC/EAN Ks <Ksstatus,EAN status,supplementals status,separator char>
PDF417 K[ <K[status,,fixed code length status,fixed code length>
Code 128 Kt <Ktstatus,fixed length,length,,,,,,>
UCC/EAN-128
(subset of Code 128)
Kt
<Kt,,,UCC/EAN-128 status,output format,application record sepa-
rator status,application record separator character,application
record brackets,application record padding
Codabar Kq
<Kqstatus,start & stop match status,start & stop output sta-
tus,large intercharacter gap,fixed code length status,fixed code
length,check digit type,check digit output>
Code 93 K! <K!status,fixed code length status,fixed code length>