Partial Output
8-16 MS-820 Industrial Bar Code Scanner User’s Manual
8–Outputs
Partial Output
Status
Start Position
Partial Length
Definition: When enabled, allows you to pre-select portions of labels to be transmit-
ted by the scanner.
Usage: In Multilabel mode, partial output is performed on each separate
label. For example, if Start Position is set to 3 and Partial Length is
set to 5, the following labels are transmitted as follows:
1234567890 as 34567
1234 as 34
123456789,abcde as “34567,cde” (two labels with separator)
12 as [blank]
Serial Cmd: <KY status,start postion,length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Definition: Allows you to determine the first character from the beginning of a label
to transmit.
Serial Cmd: <KYstatus,start postion,length>
Default: 1
Options: 1 to 2710
Definition: Allows you to determine the number of characters to be transmitted.
Serial Cmd: <KYstatus,start postion,length>
Default: 63
Options: 1 to 2710