Seitenansicht 44
MS-Connect 210 User’s Manual 2-17
Using Ethernet
Frame Trailer (Postamble) Flags
The Frame Trailer (Postamble) Flags field describes the trailer portion of the serial frame and the
processing
options. It is only effective in the Send_with_Response service when Framing
is enabled in the Receive Flags.
Note: The Receive Length field should be set to a value large enough for the data and
trailer portions even if the Strip option is enabled.
Frame Trailer (Postamble)
The Frame Trailer (Postamble) field contains the byte values expected at the end of a valid
serial input frame. The number of significant bytes comes from the Frame Trailer (Postamble)
Flags field.
Data
The Data field contains the bytes that will be output on the serial port. The length of this
field should equal at least the amount of data specified in Send Length, but can be longer
to simplify programming. In a Get_Attribute_Single or Send_with_Response reply it contains
the incoming serial data acquired.
Bit (0 = LSB) Status Flag
0-2 Postamble length (1-4 bytes)
3 Reserved
4 Strip — Strip the trailer from the response
5-7 Reserved