6-4 MS-Q Imager User’s Manual
Illumination
Illumination
The MS-Q Imager’s illumination system is
composed of four visible LEDs and six
infrared (IR) LEDs as shown at right. Both
visible and IR LEDs can be controlled
independently. IR LEDs can also be set to
low power.
For information about the laser target, see
Laser Target on page 6-3.
IR LEDs
Some inks may be incompatible with IR
LEDs. If you experience trouble reading
symbols printed in non-standard inks, try
reducing the intensity of the IR LEDs by reading the IR LEDs Low Intensity symbol
below.
You can also disable the IR LEDs by reading the
IR LEDs Off, Visible LEDs On
symbol.
Continuous Illumination
Note: Continuous Illumination is only supported in Rev 5 hardware and earlier.
Note: Continuous Illumination is only recommended for cabled readers, due to battery
consumption.
Visible LEDs
Visible LEDs
IR LEDs
IR LEDs
IR LEDs Low Intensity IR LEDs Off, Visible LEDs On
Visible LEDs Off, IR LEDs On
Restore LEDs (Default)
Turns off the near field IR LEDs.
Does not turn off visible LEDs.
Useful for highly reflective surfaces.
Turns off near field IR LEDs.
Turns off IR
LEDs and turns
on visible LEDs.
Returns visible and
IR LEDs to ON at
100% intensity.
Enable Continuous
Illumination
Disable Continuous
Illumination (Default)
Our premium databases for XRumer and GSA Search Engine Ranker are just what you need! What do our databases include? • Active links: Get access to constantly updated lists of active links from profiles, posts, forums, guestbooks, blogs, and more. No more wasting time on dead links! • Verified and identified links: Our premium databases for GSA Search Engine Ranker include verified and identified links, categorized by search engines. This means you get the highest quality links that will he