Microscan MS-4Xi Bedienungsanleitung Seite 241

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 360
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 240
MS-4Xi Imager User Manual
10-15
Camera and IP Setup
Pixel Sub-Sampling
4:1
At 4:1, 4 pixel signals from 2 adjacent rows and columns are combined so that only 1 pixel
is output for every 4 pixels sampled. An image with the dimensions 640 x 480 is scaled to
320 x 240.
Since the resolution of the output image is reduced, the frame rate will increase, but not by
the factor of the image reduction. This is due to the overhead time of digital pixel data
processing and minimum row time requirements of the image sensor.
16:1
At 16:1, 16 pixel signals from 4 adjacent rows and columns are combined so that only 1
pixel is output for every 16 pixels sampled. An image with the dimensions 640 x 480 will be
scaled to 160 x 120.
Since the resolution of the output image is reduced, the frame rate will increase, but not by
the factor of the image reduction. This is due to the overhead time of digital pixel data
processing and minimum row time requirements of the image sensor.
Definition: Pixel Sub-Sampling shows an entire captured image by averaging signals
from adjacent pixels.
Usage: <K542,pixel sub-sampling,AEC/AGC mode,AEC/AGC brightness>
Default: Disabled
Options: 0 = Disabled
1 = 4:1
2 = 16:1
Seitenansicht 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 359 360

Kommentare zu diesen Handbüchern

Keine Kommentare