Microscan HE45T Bedienungsanleitung Seite 25

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 102
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 24
Batch Operation
Getting Started
1
Rev 2.0.0, Jan 2009 HawkEye™ 45T User Manual 1-15
RS232 Considerations
•In RS-232 Batch Cable - Detect mode, the HE45T will detect if it is
connected to a powered serial cable, and will send the data. If a powered
serial cable is not connected or if the power adapter is not connected to the
serial cable, the HE45T will buffer the data. When the HE45T is then
connected to a powered serial cable, the data will automatically upload.
•In RS-232 Cabled - No Power mode, the HE45T will behave as if it is
always connected even though the serial cable is disconnected or the power
adapter is unplugged. Scanned data will be sent, regardless of connection
status. Data scanned in Cabled mode will be lost if the HE45T is not
connected to the serial cable. It will not buffer the data, unless Send & Store
mode has been enabled.
Note: If you are in RS232 Cabled-No Power mode, when you place a reader in a
charger, the reader will behave as if it is being cabled, and download the data.
THE DATA WILL BE ERASED FROM MEMORY. To disable this feature, scan
the RS232 Cable - Detect code.
FIGURE 1–11. RS-232 Batch Cable - Detect & Cabled - No Power Codes
RS-232 Batch Cable - Detect (Default)
RS-232 Cabled - No Power
M073_02
M074_02
Seitenansicht 24