Specifications
Certification and
Specifications
B
Rev 2.0.0, Jan 2009 HawkEye™ 40T User Manual B-5
Rotational Tolerance: ± 18
Target Beam: Class 2M Visible Laser Diode at 630 nm
Ambient Light Immunity: Sunlight: Up to 9,000ft-candles/98,890 lux
Shock: Withstands multiple drops of 6.56 feet
(2 meters) concrete
Optional Cable Interfaces: USB (Full Speed), RS-232 & PS/2
Memory: 4MB of memory for data and user programs
Programming: Use programming Data Matrix code
User Environment
Operating Temperature: 0° C to 40° C (32° F to 104° F)
Storage Temperature: -20° C to 60° C (-4° F to 140° F)
Humidity: 5% to 95% non-condensing
Decode Capability: Data Matrix, PDF417, QR Code, MicroQR
Code, Code 39, Code 128, UPC/EAN/JAN,
Int 2 of 5, Codabar, Code 93
Image Output Options: JPEG or BMP (Uncompressed)
Field Selection: Near or Far
Resolution Selection: SXGA (1024 x 640)
Time Stamp: Interval Logging