Seite 1 - User’s Manual

HS-21/HS-41X Handheld ReaderUser’s ManualP/N 84-100052 Rev A

Seite 2 - Technical Support

1-2 HS-21/HS-41X Handheld Reader User’s ManualCheck Required HardwareCheck Required HardwareThe HS-21/HS-41X is shipped with one of the following cabl

Seite 3 - Limitation of Liability

8-2 HS-21/HS-41X Handheld Reader User’s ManualContinuous ReadContinuous ReadRead the following symbols to enable or disable Continuous Read.Continuous

Seite 4 - Table of Contents

HS-21/HS-41X Handheld Reader User’s Manual 8-3Advanced OperationsMirroringMirroring allows the reader to decode symbols that are reversed. When Mirror

Seite 5 - Introduction

8-4 HS-21/HS-41X Handheld Reader User’s ManualMotion DetectionMotion DetectionMotion Detection causes the reader to attempt a decode whenever it sense

Seite 6 - About This Manual

HS-21/HS-41X Handheld Reader User’s Manual 8-5Advanced OperationsWindow of InterestWindow of Interest allows you to shrink the processing area of the

Seite 7

8-6 HS-21/HS-41X Handheld Reader User’s ManualWindow of InterestLinear ModeLinear Mode is intended for use with 1D (linear) symbologies. The combinati

Seite 8 - Statement of RoHS Compliance

HS-21/HS-41X Handheld Reader User’s Manual 9-19 TerminalContentsThis section describes the Terminal interface and macro functions in ESP.Terminal View

Seite 9 - 1 Quick Start

9-2 HS-21/HS-41X Handheld Reader User’s ManualTerminal ViewTerminal ViewClick the Terminal button.You will see the following view:The Terminal interfa

Seite 10 - Check Required Hardware

HS-21/HS-41X Handheld Reader User’s Manual 9-3TerminalFindThe Find function allows you to enter text strings to be searched for in the terminal window

Seite 11 - USB Interface

9-4 HS-21/HS-41X Handheld Reader User’s ManualSendSendThe Send function allows you to enter text commands and then send them to the reader. (See Text

Seite 12 - RS-232 Interface

HS-21/HS-41X Handheld Reader User’s Manual 9-5TerminalMacrosMacros can be stored in a macro selection bar, edited in a separate window, and executed b

Seite 13 - Install ESP

Quick StartHS-21/HS-41X Handheld Reader User’s Manual 1-3USB InterfaceNote: The USB interface draws its power from the host computer.USB Configuration

Seite 14 - Select Model

9-6 HS-21/HS-41X Handheld Reader User’s ManualTerminal Right-Click MenuTerminal Right-Click MenuRight click in the terminal window to display the foll

Seite 15

HS-21/HS-41X Handheld Reader User’s Manual 9-7TerminalTerminal Dropdown MenuThe terminal dropdown menu allows you to capture and save current text, an

Seite 16 - Connect Symbol

9-8 HS-21/HS-41X Handheld Reader User’s ManualTerminal Dropdown Menu

Seite 17 - Configure the Reader

HS-21/HS-41X Handheld Reader User’s Manual 10-110 Utilities ContentsThis section explains ESP’s Utilities features. These include Device Control, an i

Seite 18 - Save Changes in ESP

10-2 HS-21/HS-41X Handheld Reader User’s ManualDevice ControlDevice ControlThis feature allows you to delete stored errors, to reboot the reader, and

Seite 19 - 2 Using ESP

HS-21/HS-41X Handheld Reader User’s Manual 10-3UtilitiesDifferences from DefaultClicking the Differences from Default button will cause ESP to check a

Seite 20

10-4 HS-21/HS-41X Handheld Reader User’s ManualFirmwareFirmwareThe Firmware view in ESP Utilities is a simple way to update and verify your reader’s f

Seite 21 - Application Mode

HS-21/HS-41X Handheld Reader User’s Manual 10-5UtilitiesID and Firmware VersionAnother way to query the 2D Engine for its identifying information is b

Seite 22 - Tree Controls

10-6 HS-21/HS-41X Handheld Reader User’s ManualAdvancedAdvancedThe Advanced tab in Utilities features an archive of all batch files containing reader

Seite 23 - Menu Toolbar

HS-21/HS-41X Handheld Reader User’s Manual A-1AppendicesContentsAppendix A General Specifications ...

Seite 24 - New Model

1-4 HS-21/HS-41X Handheld Reader User’s ManualRS-232 InterfaceRS-232 InterfaceNote: Unlike USB, the RS-232 interface does not draw its power from the

Seite 25 - Preferences > General Tab

A-2 HS-21/HS-41X Handheld Reader User’s ManualGeneral SpecificationsAppendix A — General SpecificationsMechanicalEnvironmentalOperating temperature: –

Seite 26 - Preferences > Terminal Tab

HS-21/HS-41X Handheld Reader User’s Manual A-3AppendicesRead RangesNarrow Bar Read RangeSTANDARD DENSITY1D.0050” (.127 mm) 3.7 to 5.0” (94 to 127 mm).

Seite 27 - Sizing Information

A-4 HS-21/HS-41X Handheld Reader User’s ManualGeneral SpecificationsFIS and Demo Kit Options; AccessoriesSafety CertificationsFCC, CE, RoHS/WEEEISO Ce

Seite 28 - Preferences > Advanced Tab

HS-21/HS-41X Handheld Reader User’s Manual A-5AppendicesAppendix B — Electrical SpecificationsPower RequirementsReader @ 5VDC (mA): Typical: Less than

Seite 29 - Use Default Storage Location

A-6 HS-21/HS-41X Handheld Reader User’s ManualConfiguration SymbolsAppendix C — Configuration SymbolsA1Default to USB (HID)A2USB Keyboard (Windows)USB

Seite 30 - Model Memo

HS-21/HS-41X Handheld Reader User’s Manual A-7AppendicesA1UART Flow Control None (Default)A2UART Flow Control HardwareA3RS-232 Raw Mode (Default)A4RS-

Seite 31 - Connection Wizard

A-8 HS-21/HS-41X Handheld Reader User’s ManualConfiguration SymbolsA1Postamble - CR (Serial Only)A2Postamble - CommaA3Postamble - LF (Serial Only)A4Po

Seite 32 - Bar Code Dialog

HS-21/HS-41X Handheld Reader User’s Manual A-9AppendicesA1Data Matrix OnA2Data Matrix OffImportant: If you disable the Data Matrix symbology, programm

Seite 33 - Send/Receive

A-10 HS-21/HS-41X Handheld Reader User’s ManualConfiguration SymbolsA1Code 93 On (Default)A2Code 93 OffA3Code 128 On (Default)A4Code 128 OffB1Composit

Seite 34 - Advanced Options

HS-21/HS-41X Handheld Reader User’s Manual A-11AppendicesC2EAN Status Enabled (Default)C3EAN Status DisabledC4UPC-E as UPC-A EnabledD1UPC-E as UPC-A D

Seite 35 - 3 Basic Operations

Quick StartHS-21/HS-41X Handheld Reader User’s Manual 1-5Install ESPESP Software is Microscan’s configuration and testing software. Use ESP to set up

Seite 36 - Practice Targeting

A-12 HS-21/HS-41X Handheld Reader User’s ManualConfiguration SymbolsA1Pharmacode Bar Width Status Fixed ThresholdA2Pharmacode Direction Forward (Defau

Seite 37 - Motion Detect Mode

HS-21/HS-41X Handheld Reader User’s Manual A-13AppendicesConfiguration Symbol ReferenceBeeperBeep Off ...

Seite 38 - Dual Optics

A-14 HS-21/HS-41X Handheld Reader User’s ManualConfiguration SymbolsRS-232 SettingsReset to RS-232 Defaults...

Seite 39 - Dual Optics Examples

HS-21/HS-41X Handheld Reader User’s Manual A-15AppendicesComposite Off (Default)...

Seite 40 - Operational Feedback

A-16 HS-21/HS-41X Handheld Reader User’s ManualConfiguration SymbolsUSB SettingsDefault to USB (HID) ...

Seite 41 - 4 Communications

HS-21/HS-41X Handheld Reader User’s Manual A-17AppendicesAppendix D — Serial CommandsText CommandsText commands may be sent to the reader in RS-232 or

Seite 42 - Communications by ESP

A-18 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsExample 1 (make the reader beep 3 times):#%03 Expected output: should make reader beep 3

Seite 43 - Communications Overview

HS-21/HS-41X Handheld Reader User’s Manual A-19Appendices0xEE 0xEE 0xEE 0xEE 0x49 0x00 0x00 0x03 0x3CThis executes the info command, “I” in text comma

Seite 44

A-20 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsCommand Types#Causes the reader to beep the specified number of times; data contains the

Seite 45

HS-21/HS-41X Handheld Reader User’s Manual A-21Appendices9Requests the reader to delete a file from its storage; data contains the file name, terminat

Seite 46 - Data Bits (RS-232)

1-6 HS-21/HS-41X Handheld Reader User’s ManualSelect ModelSelect ModelWhen you start ESP, the following menu will appear:1. Click the HS-21/HS-41X but

Seite 47 - Preamble

A-22 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsGGet setting from reader; data contains a single character (0-255), which is the setting

Seite 48 - Postamble

HS-21/HS-41X Handheld Reader User’s Manual A-23AppendicesTRequests the current date and time (no data).(The reader will respond with d with data conta

Seite 49 - Preamble and Postamble by ESP

A-24 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsSimple ProtocolThe file is split into blocks of 236 or less bytes each and downloaded to

Seite 50 - Keyboard Mapping

HS-21/HS-41X Handheld Reader User’s Manual A-25AppendicesReader SettingsThe host sets the reader settings using the /, O, P, Q, and = commands and rea

Seite 51 - Communications Mode

A-26 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsBinary Dip SwitchSome registers are what Microscan terms a ‘Binary Dip Switch’ where the

Seite 52 - Text Commands by ESP

HS-21/HS-41X Handheld Reader User’s Manual A-27AppendicesReader Settings TableReg Setting NameDefault (Hex)Comment04 Continuous Illumination During Re

Seite 53 - USB Keyboard Rate

A-28 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands0B Matrix 2 of 5 Symbology 1Binary Dip SwitchNote: All symbol lengths greater than 2 are

Seite 54 - Data Bits

HS-21/HS-41X Handheld Reader User’s Manual A-29Appendices1B Communications Mode 81: RS232 serial2: USB keyboard5: USB Native (HID)6: USB VComm7: USB

Seite 55 - Text Command Timeout

A-30 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands22 Serial Parity 00: None1: Odd2: Even26 Beep Volume (percent) 64 (#100)Valid Range: 0 t

Seite 56

HS-21/HS-41X Handheld Reader User’s Manual A-31Appendices2C Idle Mode Countdown Timer (ms) 64 (#100)Valid Range: 0 to 7FFFFFFF Millisec-ondsCounts dow

Seite 57 - 5 Read Cycle

Quick StartHS-21/HS-41X Handheld Reader User’s Manual 1-7Select Interface and Connect to ReaderUSB• In the communications dialog box, select the commu

Seite 58 - Read Cycle by ESP

A-32 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands34Maximum Candidate Decodes Per Read1The Reader will process up to this number of codes

Seite 59 - External Trigger

HS-21/HS-41X Handheld Reader User’s Manual A-33Appendices41 Text Commands 8Binary Dip SwitchMagic Sequence:The Magic Sequence is the string “;>PAx”

Seite 60 - Default Continuous Event

A-34 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands42 Expect Acknowledgement From Host 00: Reader doesn’t wait for acknowl-edge1: Reader w

Seite 61 - Maximum Decodes per Read

HS-21/HS-41X Handheld Reader User’s Manual A-35Appendices49 Code 39 Symbology 00: Disabled1: EnabledCode 39 Full ASCII Decoding4A Composite Codes 00

Seite 62 - Read Cycle Timeout

A-36 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands4F MSI Plessey Symbology 1Binary Dip Switch50 Aztec Symbology 1Binary Dip Switch53 Dec

Seite 63 - Read Cycle

HS-21/HS-41X Handheld Reader User’s Manual A-37Appendices59 Beep Duration 64 (#100)Valid Range: 0 to 7FFFFFFF Millisec-ondsAlso see registers: 26, A76

Seite 64 - Targeting Zone Tolerance

A-38 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands85 Trioptic Options 0Binary Dip Switch86 Motion Detection: Event 3Valid Range: (see regi

Seite 65 - Morphological Preprocessing

HS-21/HS-41X Handheld Reader User’s Manual A-39Appendices99 Decoder HD field (FOI0) Y Offset 0Valid Range: 0 to 959 pixels Decoder uses the pixels aft

Seite 66 - Camera Settings

A-40 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsADWide field (FOI1) Picture Window Upper Position0Specify upper edge of window used with

Seite 67

HS-21/HS-41X Handheld Reader User’s Manual A-41AppendicesC4 Default (Continuous) Event FF (#255)The default value of FF (idle event) dis-ables “conti

Seite 68

1-8 HS-21/HS-41X Handheld Reader User’s ManualSelect Interface and Connect to ReaderRS-232• In the Select Protocol dialog box, select the communicatio

Seite 69 - 6 Symbologies

A-42 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsEDPrefix Decode Result With AIM Sym-bology Identifiers00: Don’t prefix with AIM identifi

Seite 70 - Symbologies by ESP

HS-21/HS-41X Handheld Reader User’s Manual A-43Appendices12D Hong Kong 2 Of 5 Symbology 0Binary Dip Switch137 PDF417 Handle Invalid Shift 00: Disabled

Seite 71 - Data Matrix

A-44 HS-21/HS-41X Handheld Reader User’s ManualSerial Commands1DC Pharmacode Settings 28A40Binary Dip Switch1EA Good Read Duration (ms) C8 (#200)Valid

Seite 72

HS-21/HS-41X Handheld Reader User’s Manual A-45AppendicesCRB SystemThe CRB system is a convenient method for creating and maintaining a set of command

Seite 73 - Sample Aztec Symbol

A-46 HS-21/HS-41X Handheld Reader User’s ManualSerial CommandsCRC16.c:// crc16.c#include <crc16.h>crc_t crc( crc_t initialCrc, const unsigned ch

Seite 74 - Code 39

HS-21/HS-41X Handheld Reader User’s Manual A-47AppendicesCRC16tab.h:/* crc16tab.h * crc16 table of partial remainders generated by * mkcrctab.c with p

Seite 75 - Code 128

A-48 HS-21/HS-41X Handheld Reader User’s ManualCommunications ProtocolAppendix E — Communications ProtocolCommunications Protocol Command TableProtoco

Seite 76 - Sample BC412 Symbol

HS-21/HS-41X Handheld Reader User’s Manual A-49AppendicesAppendix F — ASCII TableDec Hex Mne Ctrl Dec Hex Ch Dec Hex Ch Dec Hex Ch00 00 NUL ^@ 32 20 S

Seite 77 - Code 93

A-50 HS-21/HS-41X Handheld Reader User’s ManualMaintenanceAppendix G — MaintenanceThe HS-21 and HS-41X require only a minimum of maintenance to operat

Seite 78 - Codabar

HS-21/HS-41X Handheld Reader User’s Manual A-51AppendicesAppendix H — Glossary of TermsAberration — The failure of an optical lens to produce an exact

Seite 79 - Interleaved 2 of 5

Quick StartHS-21/HS-41X Handheld Reader User’s Manual 1-9Configure the ReaderClick the App Mode button to make configuration changes. The following mo

Seite 80

A-52 HS-21/HS-41X Handheld Reader User’s ManualGlossary of TermsDelimited — A delimited command or field is bracketed by predefined characters.Decode

Seite 81

HS-21/HS-41X Handheld Reader User’s Manual A-53AppendicesGood Read — A decode. The successful scanning and decoding of the information encoded in a ba

Seite 82 - Pharmacode

A-54 HS-21/HS-41X Handheld Reader User’s ManualGlossary of TermsPLC — See Programmable Logic Controller.Port — Logical circuit for data entry and exit

Seite 83

1-10 HS-21/HS-41X Handheld Reader User’s ManualSave Changes in ESPSave Changes in ESPTo make changes to a configuration setting:Saving Options• Send,

Seite 84 - GS1 DataBar

HS-21/HS-41X Handheld Reader User’s Manual 2-12 Using ESPContentsThis section is designed to help you understand the structure and application of ESP.

Seite 85 - Sample PDF417 Symbol

ii HS-21/HS-41X Handheld Reader User’s ManualCopyright and DisclaimerCopyright ©2012Microscan Systems, Inc.Tel: +1.425.226.5700 / 800.762.1149Fax: +1.

Seite 86 - MicroPDF417

2-2 HS-21/HS-41X Handheld Reader User’s ManualEZ ModeEZ ModeEZ Mode offers instructions on positioning the reader in relation to a test symbol and tri

Seite 87 - Composite

HS-21/HS-41X Handheld Reader User’s Manual 2-3Using ESPApplication ModeFrom EZ Mode, you can click on the App Mode button to access specific configura

Seite 88 - Symbology Identifier

2-4 HS-21/HS-41X Handheld Reader User’s ManualTree ControlsTree ControlsTo make changes to configuration settings in the tree control menus:Hint: To s

Seite 89 - 7 I/O Parameters

HS-21/HS-41X Handheld Reader User’s Manual 2-5Using ESPMenu ToolbarFile > NewWhenever New is selected from the File menu, the default configuration

Seite 90 - I/O Parameters by ESP

2-6 HS-21/HS-41X Handheld Reader User’s ManualMenu ToolbarModelThe Model menu allows you to select between reader models. When you choose another mode

Seite 91 - No Read Notification

HS-21/HS-41X Handheld Reader User’s Manual 2-7Using ESPOptionsYou can use the Options menu to save memos and set up ESP preferences.Preferences will b

Seite 92 - Targeting

2-8 HS-21/HS-41X Handheld Reader User’s ManualMenu ToolbarPreferences > Terminal TabShow Non-Printable Characters When Show Non-Printable Character

Seite 93

HS-21/HS-41X Handheld Reader User’s Manual 2-9Using ESPPreferences > Bar Code Options TabThe Bar Code Options dialog allows you to set the size of

Seite 94

2-10 HS-21/HS-41X Handheld Reader User’s ManualMenu ToolbarPreferences > Advanced TabThe Auto Sync options at the top of the Advanced tab allow the

Seite 95 - Button Stay-Down Time

HS-21/HS-41X Handheld Reader User’s Manual 2-11Using ESPAsk to Save ESP File when QuittingWhen enabled, prompts the user to save a .esp file when endi

Seite 96 - Motion Detect Event

HS-21/HS-41X Handheld Reader User’s Manual iiiIntroductionMicroscan Limited Warranty Statement and ExclusionsWhat Is Covered?Microscan Systems Inc. wa

Seite 97 - Image Quality

2-12 HS-21/HS-41X Handheld Reader User’s ManualMenu ToolbarDocument MemoThe information you type in the Document Memo field will appear in a context-s

Seite 98

HS-21/HS-41X Handheld Reader User’s Manual 2-13Using ESPConnectThe Connect dropdown menu allows the user to access the Connection Wizard, as well as t

Seite 99 - 8 Advanced Operations

2-14 HS-21/HS-41X Handheld Reader User’s ManualMenu ToolbarViewThe View menu allows the user to move quickly between the Parameters, Imager, Terminal,

Seite 100 - Continuous Read

HS-21/HS-41X Handheld Reader User’s Manual 2-15Using ESPSend/Receive To access Receive, Save, Lock, Default, and Advanced options, click the Send/Recv

Seite 101 - Mirroring

2-16 HS-21/HS-41X Handheld Reader User’s ManualSend/ReceiveDefault Current Menu SettingsThis option returns the settings in the current tree control t

Seite 102 - Motion Detection

HS-21/HS-41X Handheld Reader User’s Manual 3-13 Basic OperationsContentsThis section explains how to practice targeting and triggering, and how to beg

Seite 103 - Window of Interest

3-2 HS-21/HS-41X Handheld Reader User’s ManualPractice TargetingWhen first connecting, allow approximately 3 seconds for the reader to initialize.1. H

Seite 104 - Linear Mode

HS-21/HS-41X Handheld Reader User’s Manual 3-3Basic OperationsMotion Detect ModeThe HS-21 or HS-41X can be placed in a presentation stand and used in

Seite 105 - Terminal

3-4 HS-21/HS-41X Handheld Reader User’s ManualDual OpticsThe reader’s dual field optical system can read small 2D symbols as well as larger 1D symbols

Seite 106 - Terminal View

HS-21/HS-41X Handheld Reader User’s Manual 3-5Basic OperationsDual Optics Examples20 mil Data Matrix5 mil Code 39Dual FieldFar FieldNear FieldDual Fie

Seite 107

iv HS-21/HS-41X Handheld Reader User’s ManualTable of ContentsTable of ContentsChapter 1 Quick Start Check Required Hardware ...

Seite 108

3-6 HS-21/HS-41X Handheld Reader User’s ManualOperational FeedbackCondition Top LED Light Sound VibrationReader Successfully Powers UpGreen LED flashe

Seite 109 - Editing a Macro

HS-21/HS-41X Handheld Reader User’s Manual 4-14 CommunicationsContentsThis section explains how to set up communications between the reader and a host

Seite 110 - Terminal Right-Click Menu

4-2 HS-21/HS-41X Handheld Reader User’s ManualCommunications by ESPCommunications by ESPClick this button to bring up the App Mode view, then click th

Seite 111 - Terminal Dropdown Menu

HS-21/HS-41X Handheld Reader User’s Manual 4-3CommunicationsCommunications OverviewWhenever you default the reader, it will return to the default sett

Seite 112

4-4 HS-21/HS-41X Handheld Reader User’s ManualUSB InterfaceUSB InterfaceThe reader is in USB Native (HID) by default.USB Native (HID)This mode is the

Seite 113 - 10 Utilities

HS-21/HS-41X Handheld Reader User’s Manual 4-5CommunicationsRS-232 InterfaceEnabling RS-232 Interface will disable USB communications and require you

Seite 114 - Device Control

4-6 HS-21/HS-41X Handheld Reader User’s ManualRS-232 InterfaceParity (RS-232)Parity is an error detection routine in which one data bit in each charac

Seite 115 - Differences from Default

HS-21/HS-41X Handheld Reader User’s Manual 4-7CommunicationsPreambleA preamble is a character or series of characters that is added to the beginning o

Seite 116 - Firmware

4-8 HS-21/HS-41X Handheld Reader User’s ManualPostamblePostambleA postamble is a character or series of characters that is added to the end of a decod

Seite 117 - ID and Firmware Version

HS-21/HS-41X Handheld Reader User’s Manual 4-9CommunicationsPreamble and Postamble by ESPCharacters can also be added to the beginning and end of data

Seite 118 - Advanced

HS-21/HS-41X Handheld Reader User’s Manual vIntroductionAztec...

Seite 119 - Appendices

4-10 HS-21/HS-41X Handheld Reader User’s ManualKeyboard MappingKeyboard MappingThe Keyboard Mapping feature provides alternatives for keyboards that d

Seite 120 - General Specifications

HS-21/HS-41X Handheld Reader User’s Manual 4-11CommunicationsCommunications ModeSome ESP Communications options are unique to the software, and do not

Seite 121

4-12 HS-21/HS-41X Handheld Reader User’s ManualCommunications ModeText CommandsWhen the Text Commands feature is enabled, the reader can accept text c

Seite 122

HS-21/HS-41X Handheld Reader User’s Manual 4-13CommunicationsUSB Keyboard RateRequests that the host polls the USB reader at the rate specified (1 to

Seite 123 - RS-232 Cable Pinouts

4-14 HS-21/HS-41X Handheld Reader User’s ManualRS-232RS-232Baud RateBaud Rate is the rate at which the reader and host transfer data. It only needs to

Seite 124 - Configuration Symbols

HS-21/HS-41X Handheld Reader User’s Manual 4-15CommunicationsText Command TimeoutText Command Timeout allows you to set the maximum time during which

Seite 125

4-16 HS-21/HS-41X Handheld Reader User’s ManualText Command Timeout

Seite 126

HS-21/HS-41X Handheld Reader User’s Manual 5-15 Read CycleContentsAfter you’ve established communications you will need to address the spatial and tim

Seite 127

5-2 HS-21/HS-41X Handheld Reader User’s ManualRead Cycle by ESPRead Cycle by ESPTo change a setting, double-click the setting and use your cursor to s

Seite 128

HS-21/HS-41X Handheld Reader User’s Manual 5-3Read CycleExternal TriggerThe External Trigger parameter allows you to determine reader behavior when tr

Seite 129

vi HS-21/HS-41X Handheld Reader User’s ManualAbout the HS-21 and HS-41X Handheld ReadersAbout the HS-21 and HS-41X Handheld ReadersThe HS-21 is a gene

Seite 130

5-4 HS-21/HS-41X Handheld Reader User’s ManualDefault Continuous EventDefault Continuous EventThis parameter allows you to determine the default state

Seite 131

HS-21/HS-41X Handheld Reader User’s Manual 5-5Read CycleMaximum Decodes per ReadMaximum Decodes per Read allows you to set how many decodes can be per

Seite 132

5-6 HS-21/HS-41X Handheld Reader User’s ManualRead Cycle TimeoutRead Cycle TimeoutRead Cycle Timeout determines the duration of the read cycle. The de

Seite 133

HS-21/HS-41X Handheld Reader User’s Manual 5-7Read CycleIgnore Duplicate Symbol TimeoutIgnore Duplicate Symbol Timeout sets the reader not to output t

Seite 134

5-8 HS-21/HS-41X Handheld Reader User’s ManualTargeting Zone ToleranceTargeting Zone ToleranceTargeting Zone Tolerance is particularly useful in envir

Seite 135 - Appendix D — Serial Commands

HS-21/HS-41X Handheld Reader User’s Manual 5-9Read CycleMorphological PreprocessingMorphological Preprocessing allows you to select the method for pro

Seite 136 - Packetized Commands

5-10 HS-21/HS-41X Handheld Reader User’s ManualCamera SettingsCamera SettingsCamera Settings allow you to set AGC Sampling Mode, to set the percentage

Seite 137

HS-21/HS-41X Handheld Reader User’s Manual 5-11Read CycleWindow of InterestThe active pixel area of the image sensor is called the Window of Interest

Seite 138 - Command Types

5-12 HS-21/HS-41X Handheld Reader User’s Manual

Seite 139

HS-21/HS-41X Handheld Reader User’s Manual 6-16 SymbologiesContentsThis section describes the various symbol types that can be decoded by the HS-21 an

Seite 140

HS-21/HS-41X Handheld Reader User’s Manual viiIntroductionStatement of Agency ComplianceThe HS-21 and HS-41X have been tested for compliance with FCC

Seite 141

6-2 HS-21/HS-41X Handheld Reader User’s ManualSymbologies by ESPSymbologies by ESPTo change a setting, double-click the setting and use your cursor to

Seite 142 - Simple Protocol

HS-21/HS-41X Handheld Reader User’s Manual 6-3SymbologiesData Matrix Data Matrix Enabled (Default) Data Matrix DisabledSample Data Matrix SymbolIf you

Seite 143 - Reader Settings

6-4 HS-21/HS-41X Handheld Reader User’s ManualQR CodeQR CodeQR Code Inverse and Standard Enabled QR Code DisabledQR Code and Micro QR Code EnabledSamp

Seite 144 - Field of Interest

HS-21/HS-41X Handheld Reader User’s Manual 6-5SymbologiesAztecAztec Enabled Aztec Disabled (Default)Sample Aztec Symbol

Seite 145 - Reader Settings Table

6-6 HS-21/HS-41X Handheld Reader User’s ManualCode 39Code 39 Code 39 Disabled Code 39 Enabled (Default)Code 39 Enable Checksum Code 39 Disable Checksu

Seite 146 - Serial Commands

HS-21/HS-41X Handheld Reader User’s Manual 6-7SymbologiesCode 128 Code 128 Enabled (Default) Code 128 DisabledSample Code 128 Symbol

Seite 147

6-8 HS-21/HS-41X Handheld Reader User’s ManualBC412BC412BC412 Enabled (Default) BC412 DisabledSample BC412 Symbol

Seite 148

HS-21/HS-41X Handheld Reader User’s Manual 6-9SymbologiesCode 93 Code 93 Enabled (Default) Code 93 DisabledSample Code 93 Symbol

Seite 149

6-10 HS-21/HS-41X Handheld Reader User’s ManualCodabarCodabar Codabar Enabled (Default) Codabar DisabledCodabar Checksum Enabled Codabar Checksum Disa

Seite 150

HS-21/HS-41X Handheld Reader User’s Manual 6-11SymbologiesInterleaved 2 of 5 Interleaved 2 of 5 Enabled (Default) Interleaved 2 of 5 DisabledInterleav

Seite 151

viii HS-21/HS-41X Handheld Reader User’s ManualStatement of RoHS ComplianceStatement of RoHS ComplianceAll Microscan readers with a ‘G’ suffix in the

Seite 152

6-12 HS-21/HS-41X Handheld Reader User’s ManualUPCUPCUPC Enabled (Default) UPC DisabledEAN Status Enabled (Default) EAN Status DisabledUPC-E as UPC-A

Seite 153

HS-21/HS-41X Handheld Reader User’s Manual 6-13SymbologiesPostalPostal Enabled Postal Disabled (Default)Supported Postal Symbologies• USPS OneCode (4C

Seite 154

6-14 HS-21/HS-41X Handheld Reader User’s ManualPharmacodePharmacodePharmacode Enabled Pharmacode Disabled (Default)Fixed Symbol Length Enabled Fixed S

Seite 155

HS-21/HS-41X Handheld Reader User’s Manual 6-15SymbologiesFixed Symbol Length StatusWhen enabled, the reader will check the symbol length against the

Seite 156

6-16 HS-21/HS-41X Handheld Reader User’s ManualGS1 DataBarGS1 DataBarAll GS1 DataBar Enabled (Default) All GS1 DataBar DisabledGS1 DataBar Expanded En

Seite 157

HS-21/HS-41X Handheld Reader User’s Manual 6-17SymbologiesPDF417 PDF417 Enabled (Default) PDF417 DisabledSample PDF417 Symbol

Seite 158

6-18 HS-21/HS-41X Handheld Reader User’s ManualMicroPDF417MicroPDF417MicroPDF417 Disabled (Default) MicroPDF417 EnabledSample MicroPDF417 Symbol

Seite 159

HS-21/HS-41X Handheld Reader User’s Manual 6-19SymbologiesCompositeComposite consists of a 1D component associated with an adjacent 2D component. A su

Seite 160

6-20 HS-21/HS-41X Handheld Reader User’s ManualSymbology IdentifierSymbology IdentifierWhen Symbology Identifier is enabled, an AIM (Association for A

Seite 161

HS-21/HS-41X Handheld Reader User’s Manual 7-17 I/O ParametersContentsThis section includes instructions on setting up conditions for changing input/o

Seite 162

HS-21/HS-41X Handheld Reader User’s Manual 1-11 Quick StartContentsThis section is designed to get your HS-21 or HS-41X Handheld Reader up and running

Seite 163 - Example CRC16 C Code

7-2 HS-21/HS-41X Handheld Reader User’s ManualI/O Parameters by ESPI/O Parameters by ESPTo change a setting, double-click the setting and use your cur

Seite 164

HS-21/HS-41X Handheld Reader User’s Manual 7-3I/O ParametersNo Read NotificationNo Read Notification allows you to enable or disable user feedback ale

Seite 165

7-4 HS-21/HS-41X Handheld Reader User’s ManualTargetingTargetingThe Targeting parameter allows you to turn the targeting LEDs on or off. They are on b

Seite 166 - Communications Protocol

HS-21/HS-41X Handheld Reader User’s Manual 7-5I/O ParametersBeeperThe Beeper parameters allow you to set the Volume, Duration, and Separation of the b

Seite 167 - Appendix F — ASCII Table

7-6 HS-21/HS-41X Handheld Reader User’s ManualVibrateVibrateThe Vibrate parameter allows you to turn Vibrate on or off. It is on by default.

Seite 168 - Appendix G — Maintenance

HS-21/HS-41X Handheld Reader User’s Manual 7-7I/O ParametersButton Stay-Down TimeButton Stay-Down Time sets the amount of time (in seconds) that the r

Seite 169

7-8 HS-21/HS-41X Handheld Reader User’s ManualMotion Detect EventMotion Detect EventMotion Detect Event allows you to determine the reader's beha

Seite 170

HS-21/HS-41X Handheld Reader User’s Manual 7-9I/O ParametersImage QualityImage Quality allows you to determine the quality of images that are output f

Seite 171

7-10 HS-21/HS-41X Handheld Reader User’s ManualImage Quality

Seite 172

HS-21/HS-41X Handheld Reader User’s Manual 8-18 Advanced OperationsContentsThis section introduces several settings that can be applied to speed up pr

Kommentare zu diesen Handbüchern

Keine Kommentare